Report Type send in Reporting Group 2 (Parameter Number 102, Parameter Size 4) Defines the type of
report sent for the Reporting Group 2.
Value Description
2 MultiSensor Report
4 Meter Report for Watt
8 Meter Report for kWh
Report Type send in Reporting Group 3 (Parameter Number 103, Parameter Size 4) Defines the type of
report sent for the Reporting Group 3.
Value Description
2 MultiSensor Report
4 Meter Report for Watt
8 Meter Report for kWh
Send Interval for Reporting Group 1 (Parameter Number 111, Parameter Size 4) Defines the time interval
when the defined report of Reporting Group 1 is sent out.
Value Description
0 — 65535 Interval (Default 720)
Send Interval for Reporting Group 2 (Parameter Number 112, Parameter Size 4) Defines the time interval
when the defined report of Reporting Group 2 is sent out.
Value Description
0 — 65535 Interval (Default 720)
Send Interval for Reporting Group 3 (Parameter Number 113, Parameter Size 4) Defines the time interval
when the defined report of Reporting Group 3 is sent out.
Value Description
0 — 32000 Interval
Technical Data
Explorer Frame Support No
SDK 5.02 pl3
Device Type Slave with routing capabilities
Generic Device Class Multilevel Switch
Specific Device Class Multilevel Power Switch